PL

Start-up in full mode

In full mode a mission starts with the helicopter “cold and dark”: everything off, rotor stopped. In simplified mode the engines are already running – you skip this step.

The checklist in the game

X shows the checklist overlay: steps done ✔, current ▶, still to do ○. The game detects completed steps itself (from the switch positions), and the switch of the current step has a green frame. When something blocks the start, the overlay says why.

The switches are in the 3D cockpit – mostly on the overhead panel (U shows the whole panel). Click a switch with the mouse, or select it with , / . and press /.

#StepHow you know it worked
1BAT – ONthe essential bus is powered, about 25 V
2AVIONICS – ONPFD, VEMD and CAD light up
3Check the CAD and voltageno red messages, voltage ≥ 24 V; click the MASTER light to acknowledge
4ROTOR BRAKE – OFFwith the brake on the start is blocked
5STROBE and NAV – ONanti-collision and position lights
6FUEL PRIME 1 and 2 – ONfuel pumps; without them the start is blocked
7ENG MAIN 1 – IDLEstarter, N1 rises, ignition, idle after about 35 s
8GEN 1 – ONthe GEN 1 message goes out, 28 V
9ENG MAIN 2 – IDLEengine 2 starts
10GEN 2 – ONthe GEN 2 message goes out
11ENG MAIN 1 and 2 – FLIGHTrotor rpm rises to 100 %
12Nr 100 %green range on the VEMD, FLI in the green
13HYD 1 and 2hydraulic pressure rises with the rotor, no HYD messages
14SAS – ONengages by itself once the autopilot has power (about 60 % Nr)
15CAD clearall messages acknowledged – ready to fly

The whole start to full rotor speed takes a little over a minute in the game.

Shortcuts

Instead of clicking you can use shortcuts: 1 battery, 2 fuel valves, 3 starter 1 (wait for idle), 4 starter 2. Then raise the collective – the engines go to FLIGHT. Release the rotor brake first with the ROTOR BRAKE switch on the overhead panel (you can bind a shortcut on the I screen).

When the start fails

MessageCauseWhat to do
BAT OFFno powerstep 1
FUEL PRIME OFFfuel pump offstep 6
ROTOR BRAKE ONrotor brakestep 4
BATT LOWweak battery, no generatorstart the second engine once generator 1 is online, or wait
START ABORTED – TOTstart temperature exceededENG MAIN lever to OFF, then IDLE again
START ABORTED – HOT STARThot startlever OFF, wait, retry
START ABORTED – HUNG STARTN1 stuck below idlelever OFF, retry
ENGINE FIREafter a fire the engine is locked out for the rest of the flight–

Step-by-step tutorial: Cold start.